Please be safe, AC is dangerous! If you don't know what you are doing, you can die! You are responsible for your own safety. About: Bharat Pi is an IoT prototyping platform for students, innovators, startups and developers. A simplified board with an all in one compute network and storage on a single board to build rapid prototypes, colleg… The explanation of the cumulative sum is now finished, the following parameter examples are the same as this, there is no explanation any more. I have to say I am getting around with the Idea to have a secondary CT. At first I was thinking the original CT that is quite big but as @Robert.Wall noted , it can be any size ct as long as you create enough windings. i had the same issue as you all, then i figure out from the documentation: it’s supposed to be a uint16 as type, not int16

Power Monitoring System Using Pzem-004t and Bharath Pi

VV][scheduler:131]: Running interval 'update' with interval=60000 last_execution=93078 (now=153079) In this project, we are using Bharat Pi which has both ESP32 microcontroller and a SimCom A7672S 4G/LTE module. To find out more detail and complete about the differences and advantages between the two, please open the previous article : Get to know PZEM-004T Electronic Modules for Electrical Measurement Tools VV][scheduler:185]: Running interval 'update' with interval=60000 last_execution=170569 (now=230572)

Die 5V Spannungsversorgung der PZEM Module muss über den Wemo kommen. Nur dann erhalte ich eine Kommunikation. Ich vermute mal, dass liegt am Potenzial für Tx und Rx. I have copied my code below, and for what you are looking for I think could be done with ESPHome Automations, use spare GPIO as switch and use the values as sensors. You can use a voltage level shifter to power the ESP82xx from the PZEM-016 module's 5V power. This may also require a 470uf 35V capacitor across the 5V line to work reliably. Tasmota Configuration ~

PZEM-004T 3 Phasen Überwachung - ioBroker Community [Tutorial] PZEM-004T 3 Phasen Überwachung - ioBroker Community

Your original problem is you have (or intend to have?) a c.t. with a 1 A secondary, whereas the instrument expects 100 mA to indicate 100 A (I presume). Your need is to get that 100 mA for 500 A load current. As @Bill.Thomson suggested, a 500 A : 100 mA c.t. would do it in one step, your alternative is to do it in two steps and use your 100 A c.t. as an interposing c.t., in which case your better solution would be a 500:5 primary c.t.; and then use 10 turns in the secondary winding of that to give you 50 At to indicate 50 A on the instrument using its original 100 A c.t. (And multiply the reading by 10.) Note: Reply voltage data is D1D2D3 = 00 E6 02, 00 E6 represent the integer-bit of the voltage, 02 represent the decimal of the voltage, the decimal is one digit, converts 00 E6 to decimal is 230; converts 02 to decimal is 2, so the current voltage value is 230.2V. I re-read this entire thread and noted several comments about swapping RX/TX so I did it physically. If you know that, and the burden that the PZEM-004T presents to the c.t, you could use a second burden to divert the major part of the current away from the PZEM. But if you get it wrong, you’ll blow it up just the same.Please take a look at my web-based app for PZEM devices. It has much broader abilities than this one.) PZEM-004T Energy Monitor: The PZEM-004T is an integrated module designed for measuring electrical parameters in an AC circuit. It can measure voltage, current, power, energy, and other electrical parameters accurately. The sensor uses non-invasive current transformers (CTs) or current coils to measure the current flowing through a wire without the need for cutting or interrupting the circuit. NAME":"HW-655 PZEM","GPIO":[0,62,0,63,6,5,0,0,0,0,0,0,0],"FLAG":0,"BASE":18} PZEM-004T version V3 ~ NAME":"HW-655 PZEM","GPIO":[0,62,0,63,0,0,0,0,0,0,0,0,0],"FLAG":0,"BASE":18} PZEM-004T version V3 ~

PZEM004T Energy Monitor with esphome How to use PZEM004T Energy Monitor with esphome

At the beginning of the program, the Preferences library is initialized with a unique namespace, which will be used to store the configuration settings.Due to rising energy costs, people are finding ways to monitor their energy consumption to make energy saving measures for their home. The goal for this project is to make a DIY power meter using the PZEM-004T v3 to monitor your power consumption, and since IoT is the new norm for remote monitoring, we can also interface the power meter with an IoT dashboard through Wi-Fi connection using the Wemos D1 mini microcontroller to visualize the meter readings online where you can access it using your computer or smartphone. as far as i can remember (sorry but my pzem04 is left alone with a remote bluetooth serial dongle inside the electrical panel and i have no access to it..) i could not get it to work with the serial port of the raspberry, i had to use a dedicated USB to serial adapter, so yes: it should work.